Water and wastewater disinfection, household/industrial bleach, and PVC/plastics and chemical manufacturing.

OSHA PEL
1 ppm
Ceiling
NIOSH REL
0.5 ppm
Ceiling (15-minute)
IDLH
10 ppm
Molecular weight
70.9 g/mol

These are federal OSHA limits. The PEL shown is the federal OSHA value. About two dozen states run their own OSHA-approved plans, and some — notably California (Cal/OSHA) — enforce lower or additional exposure limits. If you work under a state plan, check your state's PEL and enter it as a custom limit in the calculator.

Recommended cartridge: Acid Gas (AG) — White band

An APR fitted with the correct cartridge is only adequate up to its MUC (below) — the cartridge must be able to capture chlorine. Low IDLH (10 ppm) sharply limits the maximum-use concentration; cartridge must be NIOSH-approved specifically for chlorine. Above ~5 ppm / at IDLH use supplied air or SCBA. Good warning properties (irritant odor near 0.3 ppm). You must establish a change-out schedule; never rely on taste or smell. See the cartridge & filter guide.

The OSHA limit for chlorine is a ceiling value, not an 8-hour average. The MUC method below is defined for time-weighted limits, so apply professional judgment.

Calculator for Chlorine

Inputs

Chlorine exposure

Unit
ppm

This is the measured airborne level from air monitoring / an exposure assessment by a qualified person — not a guess. No sampling data yet? See how to get an exposure concentration.

ppm

Presets fill the OSHA PEL. Many IH programs use the most protective of the OSHA PEL, NIOSH REL, or ACGIH TLV — enter whichever limit you use and the calculator applies it.

ppm

Enter molecular weight to convert values when you switch between ppm and mg/m³.

Result

Enter a concentration and an exposure limit to see the compliant respirators and their Maximum Use Concentration.

Hazard ratio = concentration ÷ OEL · Minimum APF must meet or exceed it · MUC = APF × OEL (capped at IDLH). Source: OSHA 29 CFR 1910.134(d)(3)(i)(A), Table 1 — Assigned Protection Factors. Last verified 2026-07-16.

Maximum use concentration for Chlorine by respirator

MUC = APF × the OSHA PEL (1 ppm), capped at the IDLH (10 ppm). Use this as a reference for the highest concentration each respirator class may be used at.

RespiratorAPFMUC (ppm)
Air-Purifying Respirator · Quarter mask55
Air-Purifying Respirator · Half mask1010
Supplied-Air Respirator (Airline) · Half mask · Demand1010
Self-Contained Breathing Apparatus · Half mask · Demand1010
Powered Air-Purifying Respirator · Helmet / hood2510IDLH
Powered Air-Purifying Respirator · Loose-fitting facepiece2510IDLH
Supplied-Air Respirator (Airline) · Helmet / hood · Continuous flow2510IDLH
Supplied-Air Respirator (Airline) · Loose-fitting facepiece · Continuous flow2510IDLH
Air-Purifying Respirator · Full facepiece5010IDLH
Powered Air-Purifying Respirator · Half mask5010IDLH
Supplied-Air Respirator (Airline) · Full facepiece · Demand5010IDLH
Supplied-Air Respirator (Airline) · Half mask · Continuous flow5010IDLH
Supplied-Air Respirator (Airline) · Half mask · Pressure-demand / positive-pressure5010IDLH
Self-Contained Breathing Apparatus · Full facepiece · Demand5010IDLH
Powered Air-Purifying Respirator · Full facepiece1,00010IDLH
Supplied-Air Respirator (Airline) · Full facepiece · Continuous flow1,00010IDLH
Supplied-Air Respirator (Airline) · Full facepiece · Pressure-demand / positive-pressure1,00010IDLH
Self-Contained Breathing Apparatus · Full facepiece · Pressure-demand / positive-pressure10,00010IDLH

Notes

NIOSH REL Ceiling 0.5 ppm [15-min]. OSHA PEL Ceiling 1 ppm (Table Z-1). IDLH 10 ppm. Neither agency sets an 8-hr TWA. NPG conversion 1 ppm = 2.90 mg/m3; MW 70.9.

Sources

Data confidence: high. Values are cited from OSHA and NIOSH but should be verified against the current source and a qualified professional before use. See how this works.