Hydrogen sulfide respirator selectionH2S

Oil & gas (sour gas) production and refining, wastewater/sewer systems, pulp & paper, and mining.

OSHA PEL
20 ppm
Ceiling
NIOSH REL
10 ppm
Ceiling (10-minute)
IDLH
100 ppm
Molecular weight
34.08 g/mol

These are federal OSHA limits. The PEL shown is the federal OSHA value. About two dozen states run their own OSHA-approved plans, and some — notably California (Cal/OSHA) — enforce lower or additional exposure limits. If you work under a state plan, check your state's PEL and enter it as a custom limit in the calculator.

Cartridge (limited use): Acid Gas (AG) — PAPR or gas-mask canister only (no negative-pressure CCR listed) — White band

An APR fitted with the correct cartridge is only adequate up to its MUC (below) — the cartridge must be able to capture hydrogen sulfide. OLFACTORY FATIGUE — H2S rapidly deadens smell, so odor is NOT a reliable warning at hazardous levels; because of this NIOSH lists no simple negative-pressure cartridge respirator, only PAPR and gas-mask canister. IDLH is only 100 ppm; at or above it supplied air/SCBA is mandatory. Use APR only when gas-monitored and below IDLH. You must establish a change-out schedule; never rely on taste or smell. See the cartridge & filter guide.

The OSHA limit for hydrogen sulfide is a ceiling value, not an 8-hour average. The MUC method below is defined for time-weighted limits, so apply professional judgment.

Calculator for Hydrogen sulfide

Inputs

Hydrogen sulfide exposure

Unit
ppm

This is the measured airborne level from air monitoring / an exposure assessment by a qualified person — not a guess. No sampling data yet? See how to get an exposure concentration.

ppm

Presets fill the OSHA PEL. Many IH programs use the most protective of the OSHA PEL, NIOSH REL, or ACGIH TLV — enter whichever limit you use and the calculator applies it.

ppm

Enter molecular weight to convert values when you switch between ppm and mg/m³.

Result

Enter a concentration and an exposure limit to see the compliant respirators and their Maximum Use Concentration.

Hazard ratio = concentration ÷ OEL · Minimum APF must meet or exceed it · MUC = APF × OEL (capped at IDLH). Source: OSHA 29 CFR 1910.134(d)(3)(i)(A), Table 1 — Assigned Protection Factors. Last verified 2026-07-16.

Maximum use concentration for Hydrogen sulfide by respirator

MUC = APF × the OSHA PEL (20 ppm), capped at the IDLH (100 ppm). Use this as a reference for the highest concentration each respirator class may be used at.

RespiratorAPFMUC (ppm)
Air-Purifying Respirator · Quarter mask5100
Air-Purifying Respirator · Half mask10100IDLH
Supplied-Air Respirator (Airline) · Half mask · Demand10100IDLH
Self-Contained Breathing Apparatus · Half mask · Demand10100IDLH
Powered Air-Purifying Respirator · Helmet / hood25100IDLH
Powered Air-Purifying Respirator · Loose-fitting facepiece25100IDLH
Supplied-Air Respirator (Airline) · Helmet / hood · Continuous flow25100IDLH
Supplied-Air Respirator (Airline) · Loose-fitting facepiece · Continuous flow25100IDLH
Air-Purifying Respirator · Full facepiece50100IDLH
Powered Air-Purifying Respirator · Half mask50100IDLH
Supplied-Air Respirator (Airline) · Full facepiece · Demand50100IDLH
Supplied-Air Respirator (Airline) · Half mask · Continuous flow50100IDLH
Supplied-Air Respirator (Airline) · Half mask · Pressure-demand / positive-pressure50100IDLH
Self-Contained Breathing Apparatus · Full facepiece · Demand50100IDLH
Powered Air-Purifying Respirator · Full facepiece1,000100IDLH
Supplied-Air Respirator (Airline) · Full facepiece · Continuous flow1,000100IDLH
Supplied-Air Respirator (Airline) · Full facepiece · Pressure-demand / positive-pressure1,000100IDLH
Self-Contained Breathing Apparatus · Full facepiece · Pressure-demand / positive-pressure10,000100IDLH

Notes

OSHA PEL (Table Z-2) Ceiling 20 ppm with 50 ppm acceptable maximum peak for a single 10-min period per 8-hr shift. NIOSH REL Ceiling 10 ppm [10-min]. IDLH 100 ppm. NPG conversion 1 ppm = 1.40 mg/m3; MW 34.1. Sense of smell fatigues rapidly and cannot be relied on as a warning.

Sources

Data confidence: high. Values are cited from OSHA and NIOSH but should be verified against the current source and a qualified professional before use. See how this works.