Respirator selection

Nitric acid respirator selectionHNO3

Fertilizer (ammonium nitrate) and explosives manufacture, metal etching/pickling, electronics, and oxidizer production.

OSHA PEL
2 ppm
TWA 8-hr
NIOSH REL
2 ppm
TWA 8-hr (also STEL 4 ppm)
IDLH
25 ppm
Molecular weight
63.01 g/mol

These are federal OSHA limits. The PEL shown is the federal OSHA value. About two dozen states run their own OSHA-approved plans, and some — notably California (Cal/OSHA) — enforce lower or additional exposure limits. If you work under a state plan, check your state's PEL and enter it as a custom limit in the calculator.

Recommended cartridge: Acid Gas (AG) — full facepiece — White band

An APR fitted with the correct cartridge is only adequate up to its MUC (below) — the cartridge must be able to capture nitric acid. Full-facepiece acid-gas CCR is NIOSH-listed up to the 25 ppm IDLH, but nitric acid is a strong oxidizer/corrosive whose vapors co-occur with NO2 — and NO2 is NOT reliably cartridge-removable. Evaluate the full atmosphere; if NO2 is present use supplied air/SCBA. Above IDLH supplied air/SCBA required. You must establish a change-out schedule; never rely on taste or smell. See the cartridge & filter guide.

Calculator for Nitric acid

Inputs

Nitric acid exposure

Unit
ppm

This is the measured airborne level from air monitoring / an exposure assessment by a qualified person — not a guess. No sampling data yet? See how to get an exposure concentration.

ppm

Presets fill the OSHA PEL. Many IH programs use the most protective of the OSHA PEL, NIOSH REL, or ACGIH TLV — enter whichever limit you use and the calculator applies it.

ppm

Enter molecular weight to convert values when you switch between ppm and mg/m³.

Result

Enter a concentration and an exposure limit to see the compliant respirators and their Maximum Use Concentration.

Hazard ratio = concentration ÷ OEL · Minimum APF must meet or exceed it · MUC = APF × OEL (capped at IDLH). Source: OSHA 29 CFR 1910.134(d)(3)(i)(A), Table 1 — Assigned Protection Factors. Last verified 2026-07-16.

Maximum use concentration for Nitric acid by respirator

MUC = APF × the OSHA PEL (2 ppm), capped at the IDLH (25 ppm). Use this as a reference for the highest concentration each respirator class may be used at.

RespiratorAPFMUC (ppm)
Air-Purifying Respirator · Quarter mask510
Air-Purifying Respirator · Half mask1020
Supplied-Air Respirator (Airline) · Half mask · Demand1020
Self-Contained Breathing Apparatus · Half mask · Demand1020
Powered Air-Purifying Respirator · Helmet / hood2525IDLH
Powered Air-Purifying Respirator · Loose-fitting facepiece2525IDLH
Supplied-Air Respirator (Airline) · Helmet / hood · Continuous flow2525IDLH
Supplied-Air Respirator (Airline) · Loose-fitting facepiece · Continuous flow2525IDLH
Air-Purifying Respirator · Full facepiece5025IDLH
Powered Air-Purifying Respirator · Half mask5025IDLH
Supplied-Air Respirator (Airline) · Full facepiece · Demand5025IDLH
Supplied-Air Respirator (Airline) · Half mask · Continuous flow5025IDLH
Supplied-Air Respirator (Airline) · Half mask · Pressure-demand / positive-pressure5025IDLH
Self-Contained Breathing Apparatus · Full facepiece · Demand5025IDLH
Powered Air-Purifying Respirator · Full facepiece1,00025IDLH
Supplied-Air Respirator (Airline) · Full facepiece · Continuous flow1,00025IDLH
Supplied-Air Respirator (Airline) · Full facepiece · Pressure-demand / positive-pressure1,00025IDLH
Self-Contained Breathing Apparatus · Full facepiece · Pressure-demand / positive-pressure10,00025IDLH

Notes

NIOSH REL TWA 2 ppm (5 mg/m3) AND STEL 4 ppm (10 mg/m3). OSHA PEL TWA 2 ppm (5 mg/m3). IDLH 25 ppm. Conversion 1 ppm = 2.58 mg/m3; MW 63.0.